Trying to repair a Hyperkin Duke Xbox controller where the left trigger doesn’t respond. Found that the resistance of this potentiometer doesn’t change when it’s moved, so I’m looking to replace it. I’m a novice with this stuff though and I’m having trouble identifying it. Any help is appreciated.

  • glibg10b@lemmy.ml
    link
    fedilink
    English
    arrow-up
    7
    ·
    1 year ago

    Found that the resistance of this potentiometer doesn’t change when it’s moved

    Are sure you’re measuring across the correct terminals? The resistance between the two terminals of the resistive portion is constant. I would expect the resistance of a failed pot to either be zero or infinite

    • pepsison52895@lemmy.oneOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      1 year ago

      There’s a test pad on the PCB labeled “LT” (left trigger). I used that and compared it’s resistance to ground to that of the right trigger’s test pad. I got about 6-10k ohms on the working one (right trigger), and 3.9-4.4 on this one.