cross-posted from: https://lemmy.world/post/3754933

While experimenting with ProtonVPN’s Wireguard configs, I realized that my real IPv6 address was leaking while IPv4 was correctly going through the tunnel. How do I prevent this from happening?

I’ve already tried adding ::/0 to the AllowedIPs option and IPv6 is listed as disabled in the NetworkManager profile.

  • dr_robot@kbin.social
    link
    fedilink
    arrow-up
    3
    ·
    1 year ago

    Wireguard easily supports dual stack configuration on a single interface, but the VPN server must also have IPv6 enabled. I use AirVPN and I get both IPv6 and IPv4 with a single wireguard tunnel. In addition to the ::/0 route you also need a static IPv6 address for the wireguard interface. This address must be provided to you by ProtonVPN.

    If that’s not possible, the only solution is to entirely disable IPv6.